The meter is a combination system that includes a service disconnect.

200 amp service wire from meter to panel. The feeder wires from the meter to both panels are thhn 2/0 copper. Plug the glass meter into the meter socket.

To highest breaker lever finished floor 200 amp, 40 circuit panel 2x 4 back supports or 5/16 molly screws. The studs don't line up correctly to allow wiring out the back of the meter into the back of the panel, so the panel will have to offset about 18 to the side of the meter (inside the building).

Firstly, lets get the terminology straight because it is confusing. The culprit is a low capacity service panel.

The 200 amp electrical panel (of course it also has a 200 amp disconnect) to be installed in the house will require it to be placed about 15 feet from the meter. The meter/main box will be provided and goes on the pole.

Interconnecting wire routes may be shown approximately, where specific receptacles or fixtures must get on an usual circuit. This section also allows any feeders that carry the entire load of the dwelling to be sized the same way, therefore, a 2/0 copper can be run to a 200 amp subpanel as long as that panels carries all the load.

It has a back feed design, with the main supply cables coming through the back of the panel and connecting to terminal blocks immediately below the entrance hole, but above the main, neutral, and ground bus bars. The square d brand 200 amp service breaker panel hasn’t changed much for decades.

The ground wire in the feeder needs to be a minimum of 8awg copper and a grounding electrode (ground rod) will need to be driven at the shop and connected to the shop subpanel by an 8awg copper wire. Advantages of a 200 amp service panel safety.

The right panel does not have this connection back to the meter base. Meter is on outside of brick building, panel will be located inside the building, between 2x4 studs.

The southwire company 500 ft. The left panel has a gec wire of #4 awg connected from that panel’s neutral/ground buss, which went back to the meter base panel (a).

how to install a subpanel / how to install main lug

how to install a subpanel / how to install main lug

100 amp subpanel off 200 amp panel 150 feet away

100 amp subpanel off 200 amp panel 150 feet away

bayite DC 6.5100V 0100A LCD Display Digital Current

bayite DC 6.5100V 0100A LCD Display Digital Current